Car center building
  • Reason for the request:
    • numerous cracks in the walls and partitions;
    • sagging of the floor slab of the first floor in some rooms.

    Within a short time, the cracks were enlarged and new ones appeared.

  • Problem:

    voids under the floor slab. Subsidence of column and belt foundations. The reasons for precipitation were:

    • ground water;
    • leaks from water intake pits;
    • non-uniform bulk soil containing construction debris at the base of foundations.
  • Goal:
    • ground stabilization based on foundations;
    • filling cavities and stabilizing the ground of the floor slab base.
  • Completed works:
    • stabilization of the ground at the base of columnar foundations, foundation beams and belt foundations;
    • lifting self-retaining brick walls to close cracks;
    • filling cavities under the floor slab;
    • soil stabilization at the base of the floor slab.
  • Methods used: Deep Stabilization, Slab Lifting.